Gas meter clearance from electrical panel?

Avis Greenholt asked a question: Gas meter clearance from electrical panel?
Asked By: Avis Greenholt
Date created: Sun, May 9, 2021 6:17 PM

Content

FAQ

Those who are looking for an answer to the question «Gas meter clearance from electrical panel?» often ask the following questions:

⛽ Gas meter clearance from window?

Gas meter regulator vent clearance distance to windows, attic vent, crawl space vent, soffit vent. 3 feet in any direction horizontally or vertically to the feature. 1 foot to a feature located below. Gas meter regulator vent clearance to electrical devices such as switches, electrical receptacles, power disconnects.

⛽ Gas meter clearance?

Gas meter clearance distance to electrical generator or electrical transformer. Gas meter clearance distance to open flame barbeque or cooker or to an incinerator or other open flame device. Gas meter clearance distance to telephone, cable or other communications connection box or terminal. Two Feet in any direction.

⛽ Gas meter clearance code?

The American Gas Association servers as the secretariat to the ANSI Accredited Standards Committee (ASC) Z223 on National Fuel Gas Code. The ASC Z223 develops and publishes ANSI Z223.1, National Fuel Gas Code.

10 other answers

The published electrical clearances for gas meters are given in a table above titled Gas meter clearance distances to electrical panels & meters (outdoors) Also see Gas meter clearance to sources of ignition A separate table titled Gas Piping Clearance Distances gives what's published for the piping itself.

Figure 2-19, “Electric and Gas Meter Set Separation Dimensions and Clearances,” found below, Figure 2-20, “Gas Meter Set Clearance From Building Openings,” on Page 2-29, and Figure 2-21, “Gas Regulator Set Clearance Requirement From Sources of Ignition,” on Page 2-30, all represent various metering facilities’ clearance requirements. If

Gas meters shall be located: In a ventilated and readily accessible area. At least 3’ from sources of ignition (including electrical circuit. breaker boxes, meters, and receptacles) or any sources of. heat that may damage the meter for inside installations. A minimum of 12” above ground for outside meter installations.

NFPA 54 (Fuel Gas Code) Section 2.7.2(c) requires that gas meters be located 3' from sources of ignition. Our PoCo requires electric meters be 3' away from gas meters. But, I don't think that gas piping is an issue as long as the clearances from the electrical panel are observed.

Clear Height in front of Panel <480V: 0.9 Meter (3 Ft) Clearance When Facing Other Electrical Panels <480V: 0.9 Meter (3 Ft) The width of the workingspace in front of the Panel: The width of Panel or 0.762 Meter which is Greater. Headroom of working spaces for panel boards (Up to 200Amp) Up to 2 Meter: Headroom of working spaces for panel boards (More than 200Amp & Panel height is max 2 Meter)

Gas Meter Clearance National Fuel Gas Code 54-5.7.2.3 **“Gas meters shall be located at least 3 ft. from sources of ignition.” **Ignition is considered anything that can ignite gas, such as electric motors, switches, outlets and most exhaust/vent terminations such as furnace and/or dryer vent. 3 foot clearance also applies to windows that ...

Updates to working space clearance around electrical equipment (according to NEC 2017) When an energized equipment requires servicing/repair but it is situated in a space with limited access : The opening to electrical equipment installed above a suspended or a lay-in ceiling must be at least 22 in. x 22 in.

Re: Distance between gas and electric National Fuel Gas Code 2.7.2(c) Gas meters shall be located at least 3 ft(0.9 m) from sources of ignition.

Figure 2-17 Gas Meter Connection Using a 5M or 7M Rotary Gas Meter (PDF, 5.3 MB) Figure 2-18 Gas Meter Connection Using an 11M or 16M Rotary Gas Meter (PDF, 5.3 MB) Figure 2-19 Electric and Gas Meter Set Separation Dimensions and Clearances (PDF, 5.3 MB) Figure 2-20 Gas Meter Set Clearance From Building Openings (PDF, 5.3 MB)

im a maintenance electrician and cant for the life of me ever remember anything in our big red book (BS7671) regards minimum distance from gas pipes, or oil pipes for that matter in OFTEC standards, as long as all pipework is correctly bonded there should be no big sparks leaping anywhere, human or otherwise.

Your Answer

We've handpicked 23 related questions for you, similar to «Gas meter clearance from electrical panel?» so you can surely find the answer!

Electrical outlet near gas meter point?

Gas meter clearance & piping distances & gas meter dimensions: This article provides a detailed table of example clearance distance specifications for natural gas meter installations, giving the distances to various building features such as windows, doors, electrical components, vents, air conditioners, and outside hose bibs.

Read more

Electrical outlet near gas meter street?

Re: Electrical Outlet within area of Main Gas Meter... Under normal circumstances, the user would not plug in or unplug a cord when they smell gas. The same goes for installing a meter at a location near a gas main, it can be ok.

Read more

How to bond a gas line to electrical panel?

Bonding gas line to electrical panel.

Read more

How big of a clearance do you need for a gas meter?

  • Underground natural gas distribution service and mains (metallic or plastic) shall have a clearance of 3 feet when running parallel or 12 inch vertical direction when crossing from any underground facility (water, sewer, electric, etc.).

Read more

How close can an electrical outlet be to a gas meter?

The NEC does not address this situation. Your local utilities may have rules on this. Use common sense. You would not want any electrical device near a gas meter that could leak. Just do not put one close to a gas meter and you know you will be safe. If you have an outdoor gas furnace and want to install a GFCI near it just make sure to install it as far from the gas meter as possible.

Read more

How close can a gas line be to an electrical panel?

That being said, you do have to maintain clearances for the panelboard. The gasline cannot be directly above the panel (or "in the shadow" of the panel) and cannot impede the required 30x36" clearance required in front of a panelboard from the floor to the ceiling.

Read more

Gas meter removed from house?

Most gas tariffs include a standing change – a set amount paid per day – removing your gas meter is the only way to stop paying for the meter and is the most cost-effective solution. If you think you have to pay a standing charge for your meter, we would suggest contacting your gas supplier for more advice and guidance.

Read more

Generator distance from gas meter?

I'd apply the clearance distance to all equipment since both safety and working space are requirements around the gas meter. A larger-flow residential gas meter may be 1-3" larger in its largest dimention than your existing one, and are typically in this range:

Read more

No gas coming from meter?

no gas coming to the meter could be because of a gas leak.... or as other posters the supply could be capped off. Transco will be able to tell. Cheapest option to start with. Did the vendor advise of any problems with the gas???

Read more

Electrical code distance from gas line?

A gas line is allowed to cross an electrical conduit. If those are buried the digging around that needs to be done by hand within 2 feet to avoid risk of damage. In any event it's your local building code compliance inspector who is the final legal authority and word on the question. On 2021-05-12 by Dj - codes against a natural gas line crossing an electrical service conduit ?

Read more

Gas cooktop clearance?

Where the manufacturers of the gas-cooking appliance and the rangehood / exhaust fan do not specify a minimum clearance rate, then the practitioner must provide a clearance rate of no less than 600mm for a rangehood and no less than 750mm for an exhaust fan, in accordance with AS/NZS 5601.1 Clause 6.10.1.1 (a).

Read more

Gas dryers clearance?

Samsung - 7.5 Cu. Ft. Stackable Gas Dryer with Steam and Sensor Dry - Fingerprint Resistant Black Stainless Steel. Model: DV50K7500GV. SKU: 4922818. User rating, 4.5 out of 5 stars with 203 reviews.

Read more

Gas range clearance?

Thermador - 6.6 Cu. Ft. Self-Cleaning Freestanding Double Oven Gas Range - Silver. Model: PRG486GDH. SKU: 7697755. User rating, 5 out of 5 stars with 3 reviews. (3) Compare. $7,819.99. Your price for this item is $ 7,819.99. Clearance.

Read more

Gas stove clearance?

A minimum clearance ‘work zone’ of 40” (102 cm) should be provided in front of a kitchen stove, with a larger 48”-60” (122-152 cm) clearance provided between other kitchen appliances. How much space should be provided above the cooking surface of a kitchen stove?

Read more

Gas meter removed from house cost?

How much does it cost to remove a gas meter? This depends on the size of the meter and the complexity of the job. However, as a guide, a standard U6 domestic meter …

Read more

Gas meter removed from house door?

Im not sure about the other things - it seems like a question for an accountant. I could presume that each director would put it into the company as a loan for tax efficiency, in any old bank account with few charges. The best company structure for mortgage purposes is the most ordinary and simpl...

Read more

Gas meter removed from house video?

Master Plumber Bryan Graham describes what to do if your gas meter is removed from your house. Call us at 281-302-6710 for more information.

Read more

Is there a required code distance between an electrical panel and gas fired heater?

four feet i think may be less that may be gas im thinking of

Read more

How do i get a meter reading from a prepayment gas meter?

Prepayment gas meter readings

To view your meter reading, simply push the button located on the front of your gas meter. Doing this will change display to show your reading. From this point just note down the reading as normal.

Read more

How do you take a meter reading from a gas smart meter?

Gas SMART meters

All you need to do is press '9' on the keypad. The word VOLUME will appear on the screen then you will see a row of digits folowed by M3. Note down the numbers before the decimal point, ignoring any zeroes at the start. This meter reading is 45.

Read more

Gas meter pulse counter meter?

This page pulls together information on DIY gas meter monitoring using pulse counting methods. If you are very lucky, your gas meter has a connector that provides access to the meters pulse output, enabling you to determine gas consumption via pulse counting, see introduction-to-pulse-counting. Safety

Read more

Water meter vs gas meter?

Show Notes : Know your water and gas meters and more. By onthehouse on June 28, 2014. KNOW YOUR WATER METER Become familiar with this system so you can shut off your water supply if necessary, test for leaks and understand your water usage. Check your company’s specific regulations before you inspect your water meter. Locate your water meter.

Read more

How to install gas line from meter?

Gas line installation tips: Get the right size pipes. Turn off the gas before installing anything. Extend the existing gas line by fitting the right pipes and valves that will reach the appliance.

Read more