What are common problems with pilot light for natural gas furnace when it takes 3 to 4 cycles to start or light.?

Elijah Nienow asked a question: What are common problems with pilot light for natural gas furnace when it takes 3 to 4 cycles to start or light.?
Asked By: Elijah Nienow
Date created: Wed, May 5, 2021 12:21 PM

Content

FAQ

Those who are looking for an answer to the question «What are common problems with pilot light for natural gas furnace when it takes 3 to 4 cycles to start or light.?» often ask the following questions:

⛽ How to start gas furnace pilot light?

Light the Standing Pilot . Place the lit match or ignited lighter tip at the pilot while depressing and holding the reset button or depressing the knob, as appropriate. Depress the button or knob for about 30 seconds. This maintains gas flow to the pilot until the thermocouple gets hot enough to open the main gas valve.

⛽ Pilot light won't stay lit gas furnace problems?

However, even the tiniest fluctuation of gas supply to the furnace could make the pilot go out. If the pilot light doesn’t stay lit, ask your neighbors if they’re also dealing with the gas supply. Should the problem persist, call the gas company for further investigations. 2.

⛽ Gas furnace pilot light?

A gas furnace's standing pilot, in which the flame is lit at all times, is sometimes referred to as a pilot light. No matter what you call it, the purpose is to serve as a small ignition flame for the gas burner.

11 other answers

Rust and deposits,,,,,,,, Best thing to do is have it cleaned PROFESSIONALLY

What are common problems with pilot light for natural gas furnace when it takes 3 to 4 cycles to start or light.? Rust and deposits,,,,,,,, Best thing to do is have it cleaned PROFESSIONALLY

Pilot Light Is Out . On old furnaces, the standing pilot light can go out due to a strong draft, a dirty orifice in the pilot burner, or dirt in the gas tube. Or the thermocouple might be faulty, causing the gas supply to shut off. The pilot light going out is one of the most common reasons that a gas furnace fails to produce heat.

10. The Furnace Leaks when AC is Running. Water condenses on the evaporator coil in your furnace, and if it leaks onto the floor, the issue is most likely a clogged drain pan or drain line, an issue covered in our AC Troubleshooting Guide. 11. The Air Coming from the Furnace Smells Bad.

Gas issues are typically the cause of pilot light failure; common problems include: Loose Pilot Valve Wiring: The pilot valve is a small device that opens and closes to release the small burst of gas that lights your pilot and burner.

STEP 8: On an older model, you may need to relight the furnace’s pilot light. “If your furnace has a pilot light—anything less than 20 years old won’t—there are instructions in your ...

If you are able to light the pilot on the gas fired appliance but when you release the gas control from it's "LIGHT" position the pilot immediately goes out, if there was a good solid flame that was clearly touching and heating the thermocouple, that is, the thermocouple was properly positioned in the pilot flame, and if you are sure that you held the control in the LIGHT position long enough for the thermocouple to heat up normally (30 seconds is plenty), then I suspect that the ...

The heater won't operate properly if the pilot flickers, is too weak or goes out, and the cause could also be blockages in the pilot tube. Another cause of a weak pilot is a faulty thermocouple.

A bad thermocouple will generally show signs of damage on the tube, the wire, or the connecting nuts. If the thermocouple is bad, the furnace usually refuses to ignite (since the pilot light no longer burns). Flame sensors are used in furnaces that use electronic ignition rather than a standing pilot light.

Academia.edu is a platform for academics to share research papers.

After looking over the vent for the problems mentioned lets check the manifold pressure at the outlet of the gas valve when the furnace is first attempting to start up. That pressure will we be listed on the furnace name plate as 'manifold pressure' generally 3.5" water column for natural gas. Let me know what you find, we can go from there.

Your Answer

We've handpicked 25 related questions for you, similar to «What are common problems with pilot light for natural gas furnace when it takes 3 to 4 cycles to start or light.?» so you can surely find the answer!

Lighting pilot light on gas furnace?

On a typical gas furnace, the pilot light is a small gas flame that acts both as an ignition source for a larger burner within the furnace, as well as an indicator of whether your furnace is actually burning and producing heat. A pilot light going out can be inconvenient because it will completely cripple your furnace.

Read more

Luxaire gas furnace pilot light parts?

Contact your nearest Luxaire® distributor for expert advice and access to Source 1™ Parts. Source 1™ Parts is the exclusive supplier of service parts and accessories for all Luxaire® residential and light commercial HVAC equipment, as well as universal HVAC replacement parts, supplies and accessories.

Read more

How to light a gas furnace pilot light?

In principle, lighting a furnace Pilot Light is not terribly complicated. Turn off the thermostat, remove a few panels to locate the pilot light, light it a...

Read more

Pilot light won t light on gas furnace?

  • There are several possible reasons why your gas furnace pilot won’t light: an ongoing draft, a faulty thermocouple , an accumulation of dirt, or an inefficient supply.

Read more

How to light a gas pilot furnace with blower?

In this episode of Repair and Replace, Vance shows how to relight the pilot light, in a standing pilot furnace. If your pilot light goes out, all you need to...

Read more

How to light a gas pilot furnace with fan?

How to light the pilot light to your furnace. Come fall time or any time your pilot light might go out, it is time to re-light your pilot light!Please thoro...

Read more

How to light a gas pilot furnace with heat?

How to light a gas pilot for a heater or furnace of the Williams type. This is a general guide and is not authoritative for all furnace types and first rule ...

Read more

How to light pilot light on ruud gas furnace?

Natasha Sioss/Moment/Getty Images Light a standing pilot on a gas stove by holding a lit match near the gas outlet. Most gas ovens have a round hole in the floor of the furnace labeled pilot, but some require access to the device through the broiler drawer.

Read more

How to light a gas pilot furnace?

Turn the knob to the "Pilot" setting, which will re-start the flow of gas to the pilot. Strike up your match or lighter. Depress the reset button, and while it is depressed, hold the match flame near the pilot opening. When the pilot is burning brightly, release the rest button.

Read more

Luxaire gas furnace pilot light goes out?

When you’re attempting to light a standing pilot light on an old furnace and still go out, you should ensure that you’re pressing the pilot button for the right amount of time. After lighting the pilot, you will have to maintain the button depressed for more than 30 seconds (up to a minute, even).

Read more

Pilot light wont stay lit gas furnace?

Check the Thermocouple Your furnace's thermocouple, if it works normally, checks to see whether the pilot light is on or off. Thermocouples detect pilot lights by sensing the heat they produce. If it determines that the pilot light is off, it shuts down the flow of gas.

Read more

Rheem criterion ii gas furnace pilot light?

I have a rheem criterion II rgph-07eauer. the pilot light isn't igniting. I tried to turn gas valve to off for 5 minutes and then back to on. turned back on electricity to unit, but still no ignition … read more

Read more

Trane xe60 gas furnace pilot light parts?

Have a Trane XE 60 Gas Furnace. Replaced thermocouple but pilot light will not stay lit. Is there to adjust the gas - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our and …

Read more

Gas heater pilot light troubleshooting problems?

Causes, problems, and troubleshooting pilot light tips. The pilot light goes out due to condensation; Improper venting; The pilot does not light; The pilot light won't stay lit; Flame too big; Flame too small; The pilot light goes out due to condensation

Read more

Modine gas heater pilot light problems?

Pilot Light Problem on Modine Heater. Hello hvac specialists. I live in Alaska and have a hanging Modine gas heater in my garage. It got down below -10 this week and my heater's pilot light won't stay lit. It is a Model PA30AB Modine heater (and yes, I think it is old - possibly even 20 years or more, but I just bought the house).

Read more

How to light pilot on gas furnace without pilot switch?

How To Light Your Pilot Light (to your Furnace) - YouTube.

Read more

What is the pilot light on a gas furnace?

  • On a typical gas furnace, the pilot light is a small gas flame that acts both as an ignition source for a larger burner within the furnace, as well as an indicator of whether your furnace is actually burning and producing heat. A pilot light going out can be inconvenient because it will completely cripple your furnace.

Read more

How to light a pilot light on a gas furnace?

Turn the knob to the "Pilot" setting, which will re-start the flow of gas to the pilot. Strike up your match or lighter. Depress the reset button, and while it is depressed, hold the match flame near the pilot opening. When the pilot is burning brightly, release the rest button.

Read more

Does a gas furnace have a pilot light?

Do You Have an Older Gas Furnace? If you have an older gas furnace, your heating unit relies on a little blue flame known as a pilot light to ensure ignition of the burners. Water heaters, gas fireplaces and old gas stoves also often have similar pilot lights. If your furnace has a round knob on the gas valve with the words OFF/ON/PILOT, you have what’s known as a standing pilot ignition.

Read more

Does my gas furnace have a pilot light?

If you have an older gas furnace, your heating unit relies on a little blue flame known as a pilot light to ensure ignition of the burners. Water heaters, gas fireplaces and old gas stoves also often have similar pilot lights. If your furnace has a round knob on the gas valve with the words OFF/ON/PILOT, you have what’s known as a standing pilot ignition.

Read more

How to check gas furnace pilot light parts?

Inspecting the Pilot Light Flame . The color of a proper pilot light flame can vary a bit depending on whether your furnace uses natural gas or propane as a fuel. A natural gas flame should be a bright blue with the tip of the flame having just a tinge of yellow. A propane flame should have a bluish-green flame with a tinge of yellow at the tip.

Read more

How to light a gas pilot furnace installation?

Turn the knob to the "Pilot" setting, which will re-start the flow of gas to the pilot. Strike up your match or lighter. Depress the reset button, and while it is depressed, hold the match flame near the pilot opening. When the pilot is burning brightly, release the rest button.

Read more

How to light a gas pilot furnace manual?

In this episode of Repair and Replace, Vance shows how to relight the pilot light, in a standing pilot furnace. If your pilot light goes out, all you need to...

Read more

How to light a gas pilot furnace model?

In principle, lighting a furnace Pilot Light is not terribly complicated. Turn off the thermostat, remove a few panels to locate the pilot light, light it a...

Read more

How to reset gas furnace without pilot light?

The small button or dial next to the pilot light opens the valve to release a little gas. It takes a few seconds to get enough gas in the pipe to start the pilot light. Newer furnaces don’t have pilot lights. Tape down the safety switch temporarily if you need to keep the panel open to prime the furnace.